archetype,working_h2_tonnes,working_energy_gwh_lhv,cushion_gas_pct,cushion_h2_tonnes,leaching_and_well_capex_m,wellhead_and_tree_capex_m,compression_train_capex_m,drying_psa_surface_capex_m,hard_capex_usd_m,cushion_gas_cost_usd_m,total_installed_usd_m,cushion_share_total_pct,capex_usd_per_kg_working,capex_usd_per_kwh_lhv,lead_time_months,equipment_bottleneck_tier Greenfield Domal Salt Cavern (1x 500k m3),5500,183.3,33.0,2709.0,32.00,4.80,28.50,16.20,81.50,12.19,93.69,13.0,17.03,0.51,60,Reciprocating API 618 compressors (24-30 mo) + brine leaching (36 mo) Repurposed Gas Salt Cavern (1x 500k m3),5500,183.3,33.0,2709.0,11.50,5.20,28.50,22.40,67.60,12.19,79.79,15.3,14.51,0.44,34,API 6A H2 wellhead qualification + upgraded PSA impurity removal Multi-Cavern Regional Hub (4x 500k m3),22000,733.3,33.0,10835.8,112.00,18.40,84.00,44.00,258.40,48.76,307.16,15.9,13.96,0.42,72,Brine disposal permitting + multi-train H2 compression queue Aboveground 300-Bar Vessel Bank (500 t H2),500,16.7,8.0,43.5,265.00,8.50,18.00,5.50,297.00,0.20,297.20,0.1,594.39,17.80,22,Pressure-vessel steel forging & ASME Sec VIII Div 3 fabrication